Veuillez utiliser cette adresse pour citer ce document : https://ds.univ-oran2.dz:8443/jspui/handle/123456789/2078
Titre: Effects of proof tests on the safety performance of safety-instrumented systems
Auteur(s): Asklou, Noureddine
Rachid, Noureddine
Mots-clés: Safety-instrumented system; proof test; average probability of failure on demand; PFDavg; safety integrity level; SIL.
Date de publication: 2018
Editeur: Université d’Oran 2 Mohamed Ben Ahmed
Résumé: The imperfection in the values of the average probability of failure on demand (PFDavg) creates uncertainty about the effectiveness of safety-instrumented system (SIS). To overcome this problem, many parameters such as dangerous failures, common cause failures, diagnostic coverage rate and proof tests are taken into consideration. In order to emphasise the importance of the proof tests and show their effects on the safety performance of the SIS, a new analytical formula is developed in this study. The impact of these tests on the SIS’s allocation of the safe integrity level (SIL) is shown through the results obtained in the present research.
URI/URL: https://ds.univ-oran2.dz:8443/jspui/handle/123456789/2078
Collection(s) :6.Institut de Maintenance et de Sécurité Industrielle

Fichier(s) constituant ce document :
Fichier Description TailleFormat 
Asklou, N. and Noureddine, R.pdf315,51 kBAdobe PDFVoir/Ouvrir


Tous les documents dans DSpace sont protégés par copyright, avec tous droits réservés.